Home
1
Products
2
Kobe (CSB) GPL second-hand deep cycle battery (C5 discharge up to 100%)_複製3
http://www.nface.com.tw/en/ Xinguo Environmental Development Co., Ltd.
Home Products used battery Kobe (CSB) GPL second-hand deep cycle battery (C5 discharge up to 100%)_複製
BO-CSB-GPL

Kobe (CSB) GPL second-hand deep cycle battery (C5 discharge up to 100%)_複製

1. The decommissioned UPS batteries are regenerated and activated by multi-national patent repair machines. 2. According to YUASA battery technical manual C5 discharge test battery performance. 3. Each battery will be connected to BMS to monitor the battery discharge voltage. 4. The discharge efficiency reaches 100% within 5 hours, and when the battery voltage reaches 10.8V within 5 hours, the performance is calculated according to the discharge time. 5. The quality of the battery is guaranteed, and the shipment is guaranteed. Another 80~99% battery for sale

6898fc034daa438299ed7e37be781d35.png

Each of the second-hand deep-cycle batteries sold by our company has been regenerated and activated by (multi-national patented repair machines), and then according to the battery technical manuals of each brand, the battery performance is tested with C5 discharge. The quality of each battery is guaranteed. Shipping is guaranteed.

The following are the battery steps of our company (detection, activation, repair) the.
 

1.Elimination of UPS batteries, after(detection, activation, repair)Regeneration and activation.

719892227f1dc214710e10c7bf5613d3.pngc4ce936762235bf13fda2a81abe799a9.png   d4be493c72793031ae6c7f9414a82c03.png      bacc8a4ee337ca084ea8416422d4fa39.png


2.According to the battery technical manual of each brand, use C5 discharge to test the battery performance (the discharge current for each battery model is different).


c788ebed54a1fa4aa2ed5b65ae0f746d.png
                According to the specifications of the battery technical manual, the discharge current of C5 is 21.3A, and the termination voltage is 10.8V


3.Each battery will be connectedBMS, monitor battery discharge voltage. (what is BMS)
f5d88d111ea86545751eb0d9b09febd5.png
 

fb00221cc980b774429d89c298aad328.png

ab776259dd7ae463abd5d3d9f8014dee.png
               The above chart is C5 discharge, the battery voltage data table every three minutes, and the time is 5 hours


10762840e1abfdbbb2970c265b91feeb.png


4.Discharge C5 according to the battery technical manual specification, the time is 5 hours, the battery voltage must not be lower than 10.8V for 100% efficiency.

5.When the battery voltage reaches 10.8V within 5 hours, the performance is calculated according to the discharge time.

For example: when the battery voltage reaches 10.8V after 4 hours of discharge, the performance is calculated as 80%(100% / 5H * 4H).


The batteries sold by our company are all tested in accordance with the specifications of the battery technical manuals of each brand. The quality is guaranteed and the shipment is guaranteed.


Kobe (CSB) HRL comes from the abbreviation of High Rate and Long life in English, which represents the design of long life and high rate discharge. On the basis of HR products, it especially improves the life of floating charge. The main features are as follows

  • When the battery is used in a safe environment, there is no need for maintenance and water replenishment, and it can be charged and discharged repeatedly.
  • Because it is completely sealed, it can be placed vertically, horizontally or sideways without compromising safety or functionality.
  • With automatic process and unique lead-calcium alloy formula, it can effectively reduce gas emissions.
  • Long life, low self-discharge and high reliability.
  • Its safety and low internal resistance bring good charge and discharge performance improvement.
  • According to the model, the battery shell can be made of flame-resistant ABS or PP material that complies with UL 94V-0.
  • Suitable for standby use.
  • High rate discharge design.
  • Deep discharge recovery.
  • Batteries are strictly tested by the patented computerized charging and discharging system.
  • Passed ISO9001, 14001, OHSMS 18001 certification.
  • Passed UL 1989 certification (File No. MH14533).
  • Air transportation complies with IATA/ICAO A67 conditions.
  • Water transport conforms to the revised category of non-dangerous goods MG27.
  • Road transport complies with [Dry charge] 49CFR 171-189 license.
 

b42c366523bb0015c7b21f99af08af2c.jpg


100~80% potency is available for sale, the quantity is limited, so buy it quickly 

1571890